View on GitHub

CIRMS Needs Report

Identifying Needs in ionizing radiation science and technology

Medical applications

The CIRMS Medical Applications subcommittee deals with diagnostic and therapeutic uses of ionizing radiation, whether isotope or accelerator sourced radiation. New topics of interest involve the growing use of proton beam therapy for more targeted cancer treatment and a need for enhanced dosimetry systems to quantify exposure levels in computerized tomography scans (CT scans). An introduction to the overall areas of interest in the medical area in the use of ionizing radiation can be found in (Appendix D). This was taken from the fourth “Needs Report” of December 2004. More complete details on all of the MPDs generated by the CIRMS Medical Applications subcommittee can be found in PDF form in prior “Needs Reports” which are accessible on the CIRMS web site.

CIRMS has been very effective in the Medical Applications area by drawing together professionals from the academic and medical communities, from the US FDA’s Center for Devices and Radiological Health (CDRH), and by involvement of the National Institutes of Health, in particular the National Cancer Institute, and of inter-agency groups such as the Biomedical Advanced Research and Development Authority (BARDA). One of CIRMS early success stories (MPD A.1.0 - National Air-Kerma Standards for Mammography) was the organization’s ability to pull together of various agencies to co-fund a needed radiation target facility at NIST so that air-kerma measurements for mammography equipment could be calibrated.

NIST, through the guidance of the CIRMS Medical Applications subcommittee, has also established radioactivity standards for nuclear medicine (MPD A.2.3) and for determining the absorbed dose-to-water for photon external beam radiation therapy (MPD A.4.1 - Absorbed-Dose-to-Water Standards for Photon External Beam Radiation Therapy). National standards for the air-kerma measurements of diagnostic X-ray beams (MPD A.5.0 - Air Kerma National Standards for Diagnostic X-ray Beams) and for the air kerma strength of photons emitted by brachytherapy sources (MPD A.6.0 - National Air Kerma Strength Standards for Photon Brachytherapy Sources) have also been established. NIST has obtained equipment, such as a medical linear accelerator, to facilitate these activities. Below is a list of the completed Measurement Program Descriptions prepared by the CIRMS Medical Applications subcommittee. One or two page descriptions of the active MPDs follow. These present the objectives, some background information and needs in each active area.

Measurement Program Descriptions (MPDs)

High Priority

Medium Priority

MPDs in progress and proposed